? phoenix contact - 11/2006 103082_01_en interface ov-24dc ? data sheet description ov-24dc ? solid-state relays for electrical isolation can be mounted directly on the pcb as interfaces or plugged in using the sim-ams socket, which can be soldered. the solid-state relays are suitable for switching ohmic, capacitive or inductive loads. relays for switching ac circuits have a zero point switch to switch on loads that are in the zero voltage crossing. they are switched off in the zero current crossing. dc loads can switch up to 1 a at 350 v dc and up to 4 a at 60 v dc, while ac loads can switch up to 5 a at 480 v ac. inductive loads must be provided with an appropriate protective circuit (e.g., free-wheeling diode or rc element). the electronic load relays have the following advantages: ? no wear, even at high switching frequencies ? no contact bounce ? no movable parts ? no electromagnetic interference ? electrically insulated housing ? compact dimensions ? high test voltage of up to 4 kv between control and load circuits make sure you always use the latest documentation. it can be downloaded at www.download.phoenixcontact.com . a conversion table is available on the internet at www.download.phoenixcontact.com/general/7000_en_00.pdf . this data sheet is valid for all products listed on the following page: solid-state relays
ov-24dc ? 103082_01_en phoenix contact 2 ordering data technical data solid-state relays with dc voltage output description type order no. pcs./pck. solid-state relay, for signal amplification and electrical isolation of the control and load circuits, can be plugged into the sim-ams plug-in base, which can be soldered, or mounted directly on the pcb with pcb connection, input/output: dc voltage (350 v dc, maximum) ov-24dc/350dc/1 2982634 10 solid-state relay, for signal amplification and electrical isolation of the control and load circuits, can be plugged into the sim-ams plug-in base, which can be soldered, or mounted directly on the pcb with pcb connection, input/output: dc voltage (60 v dc, maximum) ov-24dc/ 60dc/4 2982647 10 solid-state relays with ac voltage output description type order no. pcs./pck. solid-state relay, for signal amplification and electrical isolation of the control and load circuits, can be plugged into the sim-ams plug-in base, which can be soldered, or mounted directly on the pcb with pcb connection, input: dc voltage/output: ac voltage ov-24dc/480ac/5 2982650 10 accessories description type order no. pcs./pck. plug-in base sim-ams ... see interface catalog input data ...350dc/1 ...60dc/4 ...480ac/5 nominal input voltage u n 24 v dc 24 v dc 24 v dc operating voltage range 4.25 v dc ... 32 v dc 4 v dc ... 32 v dc voltage switching threshold "0" signal "1" signal < 1 v dc > 3.3 v dc < 1 v dc > 3.3 v dc < 1.2 v dc > 3.5 v dc typical input current at u n 15 ma 15 ma 10 ma typical switch-on time < 100 s < 100 s 1/2 period, maximum typical switch-off time < 250 s < 250 s 1/2 period, maximum switching frequency for ohmic nominal load 100 hz 100 hz 25 hz output data ...350dc/1 ...60dc/4 ...480ac/5 nominal output voltage range 1 v dc ... 350 v dc 1 v dc ... 60 v dc 12 v ac ... 530 v ac periodic peak reverse voltage ? ? 1000 v limiting continuous current (see derating curves) 1 a 4 a 5 a minimum load current 1 ma 1 ma 20 ma surge current 20 a (tp = 1 s) 25 a (tp = 1 s) 80 a (tp = 20 ms) voltage drop at maximum limiting continuous current (2-wire) 0.5 v 0.5 v 1.2 v maximum load value i 2 t??50 a 2 s leakage current when switched off 100 a 100 a 1 ma maximum phase shift (inductive loads) ? ? cos ? = 0.5 protective circuit diode for protection against polarity reversal diode for protection against polarity reversal ?
ov-24dc ? 103082_01_en phoenix contact 3 dimensions figure 1 dimensions (in mm) block diagrams figure 2 block diagram for ov-24dc/350dc/1 and ov-24dc/ 60dc/4 figure 3 block diagram for ov-24dc/480ac/5 general data ...350dc/1 ...60dc/4 ...480ac/5 test voltage input/output 4 kv rms 4 kv rms 4 kv rms ambient temperature range -20c ... +80c -20c ... +70c operating mode 100% operating factor 100% operating factor 100% operating factor assembly directly on the pcb or can be plugged in with a sim-ams socket, which can be soldered conformance with emc directive 89/336/eec and low voltage directive 73/23/eec noise immunity test according to en 61000-6-2 1 electrostatic discharge (esd) en 61000-4-2 electromagnetic hf field en 61000-4-3 fast transients (burst) en 61000-4-4 noise emission test according to en 61000-6-4 noise emission of housing en 55011 2 1 en 61000 corresponds to iec 61000 2 en 55011 corresponds to cispr11 approvals ul a a 7,7 10,5 output 34 1 (+) 2 input 43,2 25,4 5,9 7,6 17,8 30,5 35,5 1,1 3 4 2 1 ~ ~ 3 4 1 2 + - ~ ~ zero voltage switch
ov-24dc ? 103082_01_en 4 phoenix contact gmbh & co. kg ? 32823 blomberg ? germany phone: +49 - 52 35 - 30 0 ? fax: +49 - 52 35 - 34 12 00 www.phoenixcontact.com derating curves figure 4 derating curve for ov-24dc/350dc/1 figure 5 derating curve for ov-24dc/ 60dc/4 figure 6 derating curve for ov-24dc/480ac/5 ? phoenix contact 11/2006 0 0,9 1 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0,1 080 70 60 50 40 30 20 10 ambient temperature t /c a load current i/a 0 4 4,5 5 3,5 3 2,5 2 1,5 1 0,5 080 80 70 60 50 40 30 20 10 ambient temperature t / c a load current i/a distance 9 mm distance 20 mm 0 4 4,5 5 3,5 3 2,5 2 1,5 1 0,5 0 70 60 50 40 30 20 10 ambient temperature t / c a load current i/a distance 9 mm distance 20 mm
|